[KM53M88]  4-20MA Aluminum Integrated Sensor for wind speed and direction

KM53M88 KM53M88

Technical Parameters

Technical parameterParameter value
BrandKLHA
Wind speed range0~30m/s
Start wind0.2m/s
Wind speed accuracy±3%
Shell materialaluminum
Wind direction range0~360°
Wind direction resolution22.5°
Communication InterfaceDC4~20mA
PowerDC12~24V 1A
Running temperature-30~85℃

Product Size

KM53M88 KM53M88

Wiring instructions

Why choose this product?

KM53M88 KM53M88 KM53M88 KM53M88

How to use?

KM53M88

Application solution

KM53M88 KM53M88 KM53M88

Pictures

KM53M88 KM53M88 KM53M88

1. wind speed and current computing relationship

  For example, the range is 0~30m/s, the analog output is 4~20mA current signal, wind speed and current The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is wind speed range upper limit, A1 is the lower limit of the range, B2 is current output range upper limit, B1 is the lower limit, X is the currently read wind speed value, and C is the calculated current value. The list of commonly used values is as follows:
current(mA)wind speedValue (m/s) Calculation Process
40.0(30-0)*(4-4)÷(20-4)+0
51.9(30-0)*(5-4)÷(20-4)+0
63.8(30-0)*(6-4)÷(20-4)+0
75.6(30-0)*(7-4)÷(20-4)+0
87.5(30-0)*(8-4)÷(20-4)+0
99.4(30-0)*(9-4)÷(20-4)+0
1011.3(30-0)*(10-4)÷(20-4)+0
1113.1(30-0)*(11-4)÷(20-4)+0
1215.0(30-0)*(12-4)÷(20-4)+0
1316.9(30-0)*(13-4)÷(20-4)+0
1418.8(30-0)*(14-4)÷(20-4)+0
1520.6(30-0)*(15-4)÷(20-4)+0
1622.5(30-0)*(16-4)÷(20-4)+0
1724.4(30-0)*(17-4)÷(20-4)+0
1826.3(30-0)*(18-4)÷(20-4)+0
1928.1(30-0)*(19-4)÷(20-4)+0
2030.0(30-0)*(20-4)÷(20-4)+0
    As shown in the above formula, when measuring 8mA, current current is 11.5m/s。

2. conductivity and current computing relationship

  For example, the range is 0~360°, the analog output is 4~20mA current signal, conductivity and current The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is conductivity range upper limit, A1 is the lower limit of the range, B2 is current output range upper limit, B1 is the lower limit, X is the currently read conductivity value, and C is the calculated current value. The list of commonly used values is as follows:
current(mA)conductivityValue (°) Calculation Process
40.0(360-0)*(4-4)÷(20-4)+0
522.5(360-0)*(5-4)÷(20-4)+0
645.0(360-0)*(6-4)÷(20-4)+0
767.5(360-0)*(7-4)÷(20-4)+0
890.0(360-0)*(8-4)÷(20-4)+0
9112.5(360-0)*(9-4)÷(20-4)+0
10135.0(360-0)*(10-4)÷(20-4)+0
11157.5(360-0)*(11-4)÷(20-4)+0
12180.0(360-0)*(12-4)÷(20-4)+0
13202.5(360-0)*(13-4)÷(20-4)+0
14225.0(360-0)*(14-4)÷(20-4)+0
15247.5(360-0)*(15-4)÷(20-4)+0
16270.0(360-0)*(16-4)÷(20-4)+0
17292.5(360-0)*(17-4)÷(20-4)+0
18315.0(360-0)*(18-4)÷(20-4)+0
19337.5(360-0)*(19-4)÷(20-4)+0
20360.0(360-0)*(20-4)÷(20-4)+0
    As shown in the above formula, when measuring 8mA, current current is 94°。
Setup Software
Development File
Online shop
Contact Online
Contact Online and service

Email: sale@sonbest.com

BRAND: KLHA

TYPE: KM53M88

WeChat: 13918126020

SKYPE: SOOBUU

Phone: 021-51083595

QQ1: 71182854 QQ2:613035997