Technical Parameters
Technical parameter | Parameter value |
Brand | KLHA |
Wind speed range | 0~30m/s |
Start wind | 0.2m/s |
Wind speed accuracy | ±3% |
Shell material | aluminum |
Wind direction range | 0~360° |
Wind direction resolution | 22.5° |
Communication Interface | DC4~20mA |
Power | DC12~24V 1A |
Running temperature | -30~85℃ |
Product Size
Wiring instructions
Why choose this product?
How to use?
Application solution
Pictures
1. wind speed and current computing relationship
For example, the range is 0~30m/s, the analog output is 4~20mA current signal, wind speed and current The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is wind speed range upper limit, A1 is the lower limit of the range, B2 is current output range upper limit, B1 is the lower limit, X is the currently read wind speed value, and C is the calculated current value. The list of commonly used values is as follows:
current(mA) | wind speedValue (m/s) | Calculation Process |
4 | 0.0 | (30-0)*(4-4)÷(20-4)+0 |
5 | 1.9 | (30-0)*(5-4)÷(20-4)+0 |
6 | 3.8 | (30-0)*(6-4)÷(20-4)+0 |
7 | 5.6 | (30-0)*(7-4)÷(20-4)+0 |
8 | 7.5 | (30-0)*(8-4)÷(20-4)+0 |
9 | 9.4 | (30-0)*(9-4)÷(20-4)+0 |
10 | 11.3 | (30-0)*(10-4)÷(20-4)+0 |
11 | 13.1 | (30-0)*(11-4)÷(20-4)+0 |
12 | 15.0 | (30-0)*(12-4)÷(20-4)+0 |
13 | 16.9 | (30-0)*(13-4)÷(20-4)+0 |
14 | 18.8 | (30-0)*(14-4)÷(20-4)+0 |
15 | 20.6 | (30-0)*(15-4)÷(20-4)+0 |
16 | 22.5 | (30-0)*(16-4)÷(20-4)+0 |
17 | 24.4 | (30-0)*(17-4)÷(20-4)+0 |
18 | 26.3 | (30-0)*(18-4)÷(20-4)+0 |
19 | 28.1 | (30-0)*(19-4)÷(20-4)+0 |
20 | 30.0 | (30-0)*(20-4)÷(20-4)+0 |
As shown in the above formula, when measuring 8mA, current current is 11.5m/s。
2. conductivity and current computing relationship
For example, the range is 0~360°, the analog output is 4~20mA current signal, conductivity and current The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is conductivity range upper limit, A1 is the lower limit of the range, B2 is current output range upper limit, B1 is the lower limit, X is the currently read conductivity value, and C is the calculated current value. The list of commonly used values is as follows:
current(mA) | conductivityValue (°) | Calculation Process |
4 | 0.0 | (360-0)*(4-4)÷(20-4)+0 |
5 | 22.5 | (360-0)*(5-4)÷(20-4)+0 |
6 | 45.0 | (360-0)*(6-4)÷(20-4)+0 |
7 | 67.5 | (360-0)*(7-4)÷(20-4)+0 |
8 | 90.0 | (360-0)*(8-4)÷(20-4)+0 |
9 | 112.5 | (360-0)*(9-4)÷(20-4)+0 |
10 | 135.0 | (360-0)*(10-4)÷(20-4)+0 |
11 | 157.5 | (360-0)*(11-4)÷(20-4)+0 |
12 | 180.0 | (360-0)*(12-4)÷(20-4)+0 |
13 | 202.5 | (360-0)*(13-4)÷(20-4)+0 |
14 | 225.0 | (360-0)*(14-4)÷(20-4)+0 |
15 | 247.5 | (360-0)*(15-4)÷(20-4)+0 |
16 | 270.0 | (360-0)*(16-4)÷(20-4)+0 |
17 | 292.5 | (360-0)*(17-4)÷(20-4)+0 |
18 | 315.0 | (360-0)*(18-4)÷(20-4)+0 |
19 | 337.5 | (360-0)*(19-4)÷(20-4)+0 |
20 | 360.0 | (360-0)*(20-4)÷(20-4)+0 |
As shown in the above formula, when measuring 8mA, current current is 94°。